Trace width and current: IPC-2221 versus IPC-2152

Understand both approaches, when the classic formula is enough, and how to use our calculator.

7 min read

The classic IPC-2221 formula

IPC-2221 provides an empirical relationship between current, temperature rise and trace cross-section:

I = k · ΔT0.44 · A0.725

  • I in amperes, ΔT in °C above ambient, A in mil² (square thousandths of an inch).
  • k = 0.048 for external layers and 0.024 for internal layers.
  • Width = A ÷ copper thickness (1 oz/ft² ≈ 1.378 mil ≈ 35 µm).

Example: 1 A, ΔT = 10 °C, 1 oz external layer → about 16 mil² of cross-section → width ≈ 12 mil (≈ 0.30 mm).

What IPC-2152 changed

IPC-2152 was built on new measurements and shows that a trace's temperature depends heavily on its thermal environment: board thickness, nearby copper planes, material and mounting. Two practical conclusions:

  • IPC-2221's rule that an “internal trace needs twice the width” is generally conservative; with nearby planes an internal trace can dissipate well.
  • For high currents, IPC-2152 (or thermal simulation) gives more realistic results than the old curve.

In practice

  • Use the formula as a starting point and keep margin.
  • Also consider voltage drop (trace resistance) — sometimes it limits before temperature does.
  • For power, prefer shapes/planes and several vias in parallel.
  • Record the rule in Constraint Manager (one physical set per current class).